Checks physiological readings, G-load response and diagnostic behavior when state becomes invalid.
Subsystem: Audio and physiological effects
Fixture/harness: biometertests
Setup: The standalone BiometerTests harness owns the inputs, local helpers and assertion sink used by the case files below.
Build/entry point: Tests/BiometerTests.vcxproj; declared configurations: Release|x64.
BiometerDiagnosticsTests.h
Source: Tests/BiometerDiagnosticsTests.h
Run Biometer G Load Tests
Fixture: Biometer tests
Case symbol: RunBiometerGLoadTests
Source: Tests/BiometerDiagnosticsTests.h:22
- Test
- Checks expected positive/negative G-load and microgravity responses across ground, hover, ascent and re-entry conditions.
Source check messages (including original failure wording)
-
Normal negative-G response changed
-
Existing microgravity response changed
-
Ground, hover, ascent or re-entry positive-G response changed
-
Extreme negative G escaped the bounded reduction
-
Finite negative-G load still generated an invalid target or BPM
-
Simulator negative-G load generated a fault
-
Changing G direction corrupted the BPM
-
BPM failed to follow the bounded target across a G transition
-
Nonfinite G input was hidden by saturation
-
Nonfinite G input escaped the existing BPM guard
Run Biometer State Tests
Fixture: Biometer tests
Case symbol: RunBiometerStateTests
Source: Tests/BiometerDiagnosticsTests.h:81
- Test
- Checks that invalid reposition inputs cannot corrupt healthy BPM while the raw fault remains visible in diagnostics.
Source check messages (including original failure wording)
-
Reposition's negative target corrupted a healthy BPM
-
Protecting BPM hid the raw reposition fault from diagnostics
-
Overflowed reposition target changed a healthy BPM
-
BPM did not resume normal recovery after reposition
-
Previously corrupted BPM was not repaired immediately
-
Long frame overshot the recovery target
-
Normal heartbeat acceleration changed
-
Normal wake-up heartbeat changed
-
High target exceeded character maximum
-
Dead character's heartbeat restarted
-
Invalid stored state escaped recovery
-
Heartbeat audio effort escaped its valid range
-
Corrupt animation phase was not repaired
-
Animation did not wrap across multiple heartbeat cycles
-
Invalid animation input escaped normalization
Run Biometer Diagnostic Tests
Fixture: Biometer tests
Case symbol: RunBiometerDiagnosticTests
Source: Tests/BiometerDiagnosticsTests.h:124
- Test
- Run Biometer Diagnostic Tests: Healthy simulated BPM generated a diagnostic; Normal upper BPM cap was reported as a fault; Initial wake-up BPM was reported as a fault.
Source check messages (including original failure wording)
-
Healthy simulated BPM generated a diagnostic
-
Normal upper BPM cap was reported as a fault
-
Initial wake-up BPM was reported as a fault
-
Intentional zero BPM at death was reported as a fault
-
Negative G sign reversal was not diagnosed
-
Long-frame overshoot was not diagnosed
-
Previously corrupted BPM was not identified
-
Invalid model maximum was not diagnosed
-
NaN BPM escaped validation
-
Overflowed G term was not identified
-
Nonfinite calculation input escaped validation
-
Negative baseline escaped validation
-
Invalid animation state escaped validation
-
Healthy frames were written to disk
-
Fault context was not emitted before the bounded server summary
-
Biometer report lost preceding healthy frames or the raw negative value
-
Sustained fault spammed the log each frame
-
Persistent fault was never reported again
-
Recovery was not recorded locally
-
A new fault episode was not recorded
BiometerTests.cpp
Source: Tests/BiometerTests.cpp
Setup/dispatch source: named verification groups are documented under the associated case files.