Rise
The Vieneo Province
Loading...
Searching...
No Matches
Windshield Rain11 tests

Checks native windshield rain, authored wipers, rain-air controls and rendering.

Subsystem: Rain, windshields and wipers
Fixture/harness: windshieldrain11tests
Setup: Explicit setup symbols: Fixture. The standalone WindshieldRain11Tests harness owns the inputs, local helpers and assertion sink used by the case files below. Fixture is scoped to this harness; similarly named fixtures in other executables are independent.

Build/entry point: Tests/WindshieldRain11Tests.vcxproj; declared configurations: Debug|Win32, Release|Win32, Release|x64.

WindshieldRain11Tests.cpp

Source: Tests/WindshieldRain11Tests.cpp

Authored Wipers

Fixture: Windshield Rain11 tests
Case symbol: AuthoredWipers
Source: Tests/WindshieldRain11Tests.cpp:91

Test
Authored Wipers: authored wiper bead count parity; authored wiper bead motion parity; authored native blade displaces only contacted water.
Source check messages (including original failure wording)

  • open C-2 glass and blades
  • authored vertices
  • authored vertex stride
  • authored glass/blade bounds
  • authored glass/blades found
  • authored curved pane count
  • authored pane dimensions
  • parked blade retains water
  • authored wiper bead count parity
  • authored swept bead radius
  • authored wiper bead motion parity
  • authored native blade displaces only contacted water
  • authored sweep preserves water volume

Rain Air Checks

Fixture: Windshield Rain11 tests
Case symbol: RainAirChecks
Source: Tests/WindshieldRain11Tests.cpp:162

Test
Rain Air Checks: powered idle engine supplies rain air; any positive server health is serviceable; installed failed rain-air equipment.
Source check messages (including original failure wording)

  • powered idle engine supplies rain air
  • any positive server health is serviceable
  • installed failed rain-air equipment
  • failed installed unit stays INOP with R off
  • failed selected unit cannot blow rain off glass
  • no failure indication before VDAT or in excluded vehicles
  • no engine air supply
  • no electrical control power
  • absent equipment has no CAS indication
  • R off stops rain air
  • simulators and inactive vehicles excluded
  • installed E-10 equipment supplies air outside the simulator
  • simulator entry suppresses selected equipment without retaining flow or thrust loss
  • simulator exit cannot replay deselected rain air
  • rain protection works again when selected outside the simulator
  • rain air costs 0.5 percent delivered thrust
  • partial thrust loses the same fraction, not rated thrust
  • reverse thrust loses magnitude without changing direction
  • rain air cannot create thrust at idle
  • rain bleed stacks after existing anti-ice loss
  • no bleed penalty when air is off or unavailable
  • absent equipment has no thrust penalty
  • excluded vehicle has no thrust penalty
  • open pneumatic rain-removal cockpit
  • rain-air mesh stride
  • aircraft has wettable glass
  • switch-on moves water rather than instantly erasing it
  • authored glass jet weakens from aircraft-bottom to top
  • unprotected panes unchanged
  • forward glass blown up; side glass untouched
  • air curtain reduces water buildup in heavy rain

Runoff Direction Checks

Fixture: Windshield Rain11 tests
Case symbol: RunoffDirectionChecks
Source: Tests/WindshieldRain11Tests.cpp:281

Test
Runoff Direction Checks: authored glass drains downward under local gravity; side runoff has no fore/aft slant; front runoff has no lateral fanning; runoff follows the glass surface.
Source check messages (including original failure wording)

  • open authored runoff cockpit
  • runoff mesh stride
  • runoff mesh bounds
  • runoff panes found
  • authored glass drains downward under local gravity
  • side runoff has no fore/aft slant; front runoff has no lateral fanning
  • runoff follows the glass surface
  • vertical load scaling is preserved
  • lateral and longitudinal maneuver forces retain their tangential projection
  • runoff retains tracked water
  • beads visibly descend on authored panes
  • roughness does not restore the broad diagonal runoff
  • Manx includes both side windows and front glass
  • normal flight accumulates water
  • simulator entry clears beads and residue
  • simulator blocks impacts, wind and rain air while retaining geometry
  • simulator suppresses rain rendering
  • simulator exit cannot replay old water
  • new real-world rain resumes after simulator exit
  • repeated simulator entry clears new water

Save

Fixture: Windshield Rain11 tests
Case symbol: Save
Source: Tests/WindshieldRain11Tests.cpp:457

Test
Support check: verifies readback and export of the fixture image used for visual comparison.
Source check messages (including original failure wording)

  • save map
  • save image

Mask Native

Fixture: Windshield Rain11 tests
Case symbol: MaskNative
Source: Tests/WindshieldRain11Tests.cpp:463

Test
Mask Native: mask depth state; mask geometry; mask shader.
Source check messages (including original failure wording)

  • mask depth state
  • mask geometry
  • mask shader

Compare

Fixture: Windshield Rain11 tests
Case symbol: Compare
Source: Tests/WindshieldRain11Tests.cpp:482

Test
Compare: opaque interior and foreground wiper remain unchanged.
Source check messages (including original failure wording)

  • background map
  • reference background
  • world clear
  • reference cockpit mask
  • reference scene
  • reference water
  • reference end
  • reference readback
  • reference map
  • native water
  • caller state restored
  • native readback
  • opaque interior and foreground wiper remain unchanged
  • wet glass visibly rendered

Authored Visibility

Fixture: Windshield Rain11 tests
Case symbol: AuthoredVisibility
Source: Tests/WindshieldRain11Tests.cpp:539

Test
Authored Visibility: P-13's five glass components produce eight panes; natural rain is visible on authored P-13 front and side glass.
Source check messages (including original failure wording)

  • authored rain device
  • open authored visibility cockpit
  • visibility mesh stride
  • visibility mesh bounds
  • P-13's five glass components produce eight panes
  • authored interior
  • authored scene target
  • authored scene view
  • authored depth
  • authored raster
  • authored stencil
  • authored interior shader
  • authored water draw
  • authored pixels
  • natural rain is visible on authored P-13 front and side glass

Mask Format Check

Fixture: Windshield Rain11 tests
Case symbol: MaskFormatCheck
Source: Tests/WindshieldRain11Tests.cpp:629

Test
Mask Format Check: visibility mask format/resize regression; visibility mask released on reset.
Source check messages (including original failure wording)

  • visibility mask format/resize regression
  • visibility mask released on reset

Debug Check

Fixture: Windshield Rain11 tests
Case symbol: DebugCheck
Source: Tests/WindshieldRain11Tests.cpp:642

Test
Support check: inspects graphics debug messages and rejects resource/state errors reported by the fixture.
Source check messages (including original failure wording)

  • debug message

Entry-point checks

Fixture: Windshield Rain11 tests
Case symbol: main
Source: Tests/WindshieldRain11Tests.cpp:654

Test
Checks native windshield rain, authored wipers, rain-air controls and rendering. This entry point also runs the associated check groups.